Key Features
- Satin Anodised Aluminium (SAA) or any RAL colours to match décor.
- Fire tested to BS476 Part: 20 & 22 for 30-60 minutes and EN 1634 to 30 mins. **Note: To be fitted as per the global assessment. If you wish to receive a copy of this document please contact our sales team.
- Available with a flat or rounded edge and in various widths to suit any door edge.
- New build or refurbishment.
- Ideal for use in Healthcare, Retail, Schools and Commercial/Public areas.
- Length 2100mm or 2500mm.
- Single or double door configuration. Rounded 45mm & 55mm.
Product Description
Doors in hospitals suffer more than most from wear and tear resulting from high traffic levels and impact damage yet any door in a commercial or industrial building is likely to suffer from this loss of integrity.
With constant trolley and wheelchair traffic it is the leading edge of the door that suffers most from 'porter damage' which not only results in general damage to the door but also possible loss of the fire integrity of the door.
Astro-flame have overcome this problem with their range of Fire rated Door Edge Guards which are available in various sizes from 44 - 55mm width and lengths up to 2500mm.
Fitted with intumescent fire and smoke seals which are vandal-resistant yet easy to replace, these aluminium door edge guards are ideal for maintaining fire integrity and can be used on the front and back edges of fire resisting door sets.
Available in aluminium or RAL Colours up to 2500mm long & Widely specified throughout the UK healthcare market.
Product Availability
Length: Standard Length 2100mm - Longer lengths to order up to 2500mm.
Colours: Standard Satin Aluminium (SAA) colour or any RAL colour to order (Please specify RAL code).
Rounded
AFDEGR/44SAA Rounded Door Edge Guard SAA 30 min 44mm
AFDEGR/46SAA Rounded Door Edge Guard SAA 30 min 46mm
AFDEGR/55SAA Rounded Door Edge Guard SAA 60 min 55mm
Square
AFDEGF/44SAA Flat Door Edge Guard SAA 30 min 44mm
AFDEGF/46SAA Flat Door Edge Guard SAA 30 min 46mm
AFDEGF/55SAA Flat Door Edge Guard SAA 60 min 55mm
Maintenance
All interested parties, designer, specifier, main contractor and specialist installers should provide access to allow the fire stopping seals to be regularly inspected and maintained, as well as records kept of such maintenance at minimum periods of 12 months, as required by the Regulatory Reform Order, and repaired if necessary. Reference should be made to ASFP TGD 17 – Code of Practice for the Installation and Inspection of Fire Stopping.
Competency
It is vital that those entrusted to design or install a fire stopping product have the necessary levels of competence to undertake the task professionally and thoroughly. The level of competency required will be commensurate with the expected complexity of the building. All designers must eliminate, reduce or control foreseeable risks that may arise during installation, construction or maintenance when preparing or modifying designs. Clients should ensure that the principal designer and principal contractor carry out their duties under CDM regulations. The ASFP foundation course in passive fire protection provides essential knowledge as part of demonstrating competency and understanding in this key fire protection specialism.
NOTE: Standard length 2100mm - Longer Lengths and RAL Colours Also Available P.O.A