Astro Intumescent Expansion Joint Seals various sizes

£4.99
Tax included.

Key Features

  • Testing in accordance with BS 476pt 20/22 – Fire Resistance – 120 minutes Integrity.
  • IET (IEE) 17th Edition Fire Stop Compliant to Regulation 527.1-3 – Electrical Installations.
  • BS 7671-2008 Chapter 42&52 – Electrical Installations Fire Resistance.
  • Tested in accordance with EN10140-2: 2010 - Airborne Sound.
  • Tested in accordance with EN1026:2000 - Air Permeability.
  • To reinstate fire resistance through walls and floors - linear seals.
  • Movement joints +/-25%.
  • For internal use.

Product Description
Astro EJ Seal is an intumescent thermoplastic filled with flame retardants and binders which provide a high performance volume expansion and pressure seal situated in an elastomeric, acoustic rated foam which allows for high movement. They can be used in:

Properties and Specification

  • Colour Black
  • Density 75Kg/m3
  • Fire Resistance Tested in accordance with BS 476 Part 20: 1987
  • Acoustic Performance Acoustic Reduction up to 8Rw, 18DnTW
  • Air Permeability 200Pa EN 1026 - 100Pa 1581/1590 m3/h/m2
  • Expansion Ratio 1:20 Times
  • Maximum Size of Aperture 150mm
  • Seal Length 1000mm
  • Movement Capability +/- 25%
  • Once compressed EJ Seal will return to original size
  • Product Availability
  • Supplied in metre lengths. When ordering please state product code and number of metre lengths required.

2 Hour Fire Rating

  • AFEJ10/120 Astro EJ Seal 10mm Up to 10mm 12x12mm 120mins
  • AFEJ20/120 Astro EJ Seal 20mm 11 - 20mm 29x12mm 120mins
  • AFEJ25/120 Astro EJ Seal 25mm 21 - 25mm 32x20mm 120mins
  • AFEJ35/120 Astro EJ Seal 35mm 26 - 35mm 53x20mm 120mins
  • AFEJ50/120 Astro EJ Seal 50mm 36 - 50mm 61x35mm 120mins
  • AFEJ60/120 Astro EJ Seal 60mm 51 - 65mm 85x40mm 120mins
  • AFEJ75/120 Astro EJ Seal 75mm 66 - 75mm 90x50mm 120mins
  • AFEJ100/120 Astro EJ Seal 100mm 76 - 100mm 126x100mm 120mins
  • AFEJ120/120 Astro EJ Seal 120mm 101 - 120mm 147x125mm 120mins
  • AFEJ150/120 Astro EJ Seal 150mm 121 - 150mm 170x100mm 120mins

Maintenance
All interested parties, designer, specifier, main contractor and specialist installers should provide access to allow the fire stopping seals to be regularly inspected and maintained, as well as records kept of such maintenance at minimum periods of 12 months, as required by the Regulatory Reform Order, and repaired if necessary. Reference should be made to ASFP TGD 17 – Code of Practice for the Installation and Inspection of Fire Stopping.

Competency
It is vital that those entrusted to design or install a fire stopping product have the necessary levels of competence to undertake the task professionally and thoroughly. The level of competency required will be commensurate with the expected complexity of the building. All designers must eliminate, reduce or control foreseeable risks that may arise during installation, construction or maintenance when preparing or modifying designs. Clients should ensure that the principal designer and principal contractor carry out their duties under CDM regulations. The ASFP foundation course in passive fire protection provides essential knowledge as part of demonstrating competency and understanding in this key fire protection specialism.